Analysis and Release Procedure of Intermediate and Bulk Product

Analysis and Release Procedure: Purpose

Analysis and Release Procedure, The purpose of this procedure is to establish an appropriate system for analysis of intermediate stage sample (i.e. powder, granules, core tablet) and semi-finished (bulk) products (i.e. coated tablet, filled capsule) from production department for ensuring the quality by subsequent testing as well as releasing intermediate stage sample for next processing stage and semi-finished (bulk) products for packaging.

Scope:

This procedure is applicable for intermediate and semi-finished (bulk) products manufactured in general block at XX Pharmaceuticals Limited.

Definitions / Abbreviation:

Standard Operating Procedure (SOP): Standard Operating Procedure.

[] QC: Quality Control.
[] COA: Certificate of Analysis
[] SAF: Sampling Advice Form
[] Mfg. Date: Manufacturing Date
[] Exp. Date: Expiry Date
[] XX: Current version of SOP
[] Bulk Product: Any product which has completed all processing stages up to, but not including, final packaging.
[] Batch (or Lot): A defined quantity of material or product processed in one process or series of processes so that it could be expected to be homogeneous.

Responsibilities:

Sr. Executive/Executive, QC

[] To ensure that the instructions of this procedure are correctly followed.
[] To maintain the records properly as per SOP

Executive, QA

[] To perform sampling.
[] To provide SAF and sample to QC for analysis.
[] To receive report from QC dept. after completion of analysis.

Manager, Quality Control

[] To ensure that this procedure is kept up to date.
[] To confirm that the SOP reflects the required working practices.
[] To arrange training on the SOP to all concerned personnel and to ensure implementation of the SOP after training.

Head of Quality Assurance

[] Approval of the SOP.
[] To ensure the overall implementation of the SOP.

Procedure:

General Precaution(s):

[] Check the calibration status of the instruments to be used.
[] Check the validity of the working standard to be used.
[] Do not return any bulk sample to production unit to avoid batch/product mix-up.
[] Transfer excess sample to ‘Sample for Disposal’ place after approval.

Intermediate and Semi-Finished (bulk) Product Test Plan:

[] Before starting analysis ensure the test plan as Annexure-II.
[] In case of ready to fill pellets for capsule, carry out potency calculation by using assay result of representative lot of raw material & average filled weight (taken from in-process result of encapsulation stage). Dissolution test result will be taken from representative lot of raw material.
[] Perform assay & dissolution test in every 10th batch of regular commercial batch and process validation batch in case of ready to fill pellets for capsule.

Receiving and analysis:

[] Executive, Quality Assurance will collect sample of intermediate and semi-finished (bulk) product maintaining the SOP of intermediate and semi-finished (bulk) products sampling procedure.
[] Quality Assurance will provide test sample to QC according to ‘Intermediate and Semi-Finished (bulk) Product Test Plan’ (as per Annexure-II).
[] Executive, Quality Assurance will send test sample along with the Sampling Advice Form (SAF).
[] After receiving the sample, QC Executive will put the Lab. Control No. on the SAF and record all necessary information in ‘Intermediate and Semi-Finished (bulk) Product Log Register’ (as per Annexure-I).
[] After proper entry in the log book, QC Executive will keep the sample in the designated place of ‘Sample Receiving Room’.
[] QC In-charge/Sr. Executive, QC will assign the work and issue the finished product analytical work sheet to QC Sr. Executive/Executive with initial and date on every page and enter the worksheet issued by (initial and date) in the ‘Intermediate and Semi-Finished (bulk) Product Log Register’ (as per Annexure-I).
[] Sr. Executive/Executive, QC will take sample from sample receiving room and test the sample against the respective approved method of analysis.
[] Sr. Executive/Executive, QC will follow ‘Intermediate and Semi-Finished (bulk) Product Test Plan’ (as per Annexure-II) or as per requirement of SAF for analysis.
[] Record all analytical raw data and make calculation in the analyst logbook (Annexure-V) with attachment of required printout of weight(s).
[] Record the results in the work sheet with attachment of required raw data.
[] Carry out the test for assay of single sample preparation.
[] In case of instrumental analysis carried for testing, fill the instrument log properly.
[] Compare the results with the specification.
[] In case where test results go out of specification, report to designated personnel. Analysis may be repeated with proper authorization.

Release:

[] Sr. Executive/Executive, QC will compile the test report and prepare COA (as per Annexure-IV).
[] Sr. Executive/Executive, QC will check the test report, analyst log book, worksheet and COA.
[] In-charge, QC will verify the test report and approve COA if all results comply with the respective specifications.
[] If the test result does not comply with the specification follow the SOP for handling of out of specification.
[] After completion of the test, transfer left over sample in specified place labeled as “Under Test Samples” until the batch is approved.
[] After approval of the batch, transfer the excess sample to a place labeled as “Sample for Disposal” by making necessary entry in sample disposal register.
[] Sr. Executive/Executive, QC will input the necessary data in finished product trend analysis.
[] Send the approved test report with SAF and COA to Quality Assurance.

Find All Annexure Here

Annexure-I     : Intermediate and Semi-Finished (bulk) Product Log Register
Annexure-II    : Intermediate and Semi-Finished (bulk) Product Test Plan
Annexure-III   : Finished Product Analytical Worksheet
Annexure-IV   : Certificate of Analysis
Annexure-V    : Analyst Logbook

Analysis and Release Procedure of Intermediate and Bulk Product Read More »

Packaging Material Sampling and Release Procedure

Packaging Material Sampling and Release, Purpose :

The purpose of this SOP is to describe the procedure for sampling and releasing of packaging materials for pharmaceutical products.

Packaging Material Sampling and Release, Scope :

This procedure is applicable for all packaging materials received at the warehouse of  XX Pharmaceuticals Limited.

Definitions/Abbreviation:

[] SOP: Standard Operating Procedure
[] QC: Quality Control
[] GRN: Goods Received Note
[] COA: Certificate of Analysis
[] ERP: Enterprise Resource Planning
[] Sampling: It is a process of collecting the materials so that the collection shall represent the whole lot.
[] Sampling plan: Description of the number of units and/or quantity of material that should be collected.
[] Consignment: A supply of a material of particular batch intended to be used in different department.
[] Lot: A defined quantity of material made by a specified process cycle having uniform quality.

Responsibilities:

The roles and responsibility is as follows:

Officer/Executive/ Sr. Executive, Quality Control

[] To ensure that the procedure is correctly followed.
[] To maintain the records properly as per SOP.
[] To ensure that this procedure is kept up to date.
[] To confirm that the SOP reflects the required working practices.
[] To arrange training on the SOP to all concerned personnel and to ensure implementation of the SOP after training.

Executive/ Sr. Executive, Warehouse

[] To ensure availability of containers to be sampled in quarantine area.

Executive, Production

[] To arrange machine trial when required and share the report to QC with the concern of Manager,

Production.

Head of Quality Assurance

[] To ensure the overall implementation of the SOP.
[] Approval of the SOP.

 Procedure:
General Precaution(s):

[] Take sample for microbial testing first followed by other sampling.
[] Sampling should be carried out by trained personnel.

Sampling: Packaging Material Sampling and Release

[] Receive the GRN with Manufacture’s COA from the warehouse and enter the details (GRN no., lab. control no., name of material, code no., invoice/challan no., manufacturer lot no., local batch no., manufactured by, supplied by, pack size, no. of pack, total quantity and received by & date) in the ‘Packaging Material Log Register’ (as per Annexure-I) maintained in QC department for packaging material.
[] Ensure that material is received from Approved Vendor.
[] If the material is not from approved vendor or if the Manufacture’s COA for primary packaging material is not received, inform Supply Chain Management Department.
[] QC Officer/Executive or QC sampler will select the no. of container/packs to be sampled as per sampling plan and sample quantity according to ‘Sampling quantity for Packaging Material’ (as per Annexure-II) and take required no. of “SAMPLED” label.
[] For example, when the total no. of container of inner carton (secondary packaging material) is 25, then no. of container to be sampled will be Ö 25 + 1 = 5 + 1 = 6.
[] If the batch size is 3100 pcs, then 32 pcs of inner cartons will be taken from 6 different containers.

Sampling plan:

[] The n plan

The “n plan” is based on the formula n = 1 + ÖN, where N is the number of sampling units in the consignment. The value of n is obtained by simple rounding. A minimum number of containers needs to be sampled, e.g. if N is less than or equal to 4, then every container is sampled. According to this plan, samples are taken from n sampling units (containers/pack) selected at random.

Sampling plan for primary packaging material

[] In case of primary packaging material, select no. of reels/pack/ container for sampling as per “n plan”.

Collect approximately 1 feet sample of foil/film from each of selected reels of films/foils.

[] In case of bottle/cap/dropper/stopper, take randomly 10 samples from selected containers.
[] In case of Container/Jerry can/Cap for Jerry can; check physical appearance of at least 3 samples from each selected container/pack (selected as per “n plan”) and then take randomly two containers for laboratory test from selected container/pack.

Sampling plan for secondary packaging material

[] For secondary packaging material, select container/pack for sampling as per “n plan”.
[] Samples can be withdrawn from any part of the container (usually from the top layer).
[] Collect sample proportionally from the selected container/pack following ‘Sampling quantity for Packaging Material’ (as per Annexure-II).
[] In case of Shipper carton and Master carton, check physical appearance and text of at least 3 shipper cartons from each selected pack and then take randomly 3 shipper cartons for laboratory test from selected pack.
[] Inform Warehouse before going for sampling to arrange the packaging material containers.
[] Take ‘Sampled’ label, sampling tools, packaging material sampling report, sampling basket and GRN before sampling.
[] Check the physical condition and cleanliness of packaging material containers/packs before opening for sampling.
[] If any container/pack found in damaged condition, intimate warehouse in-charge.
[] Damaged containers/packs whose integrity is doubtful should be sampled and tested separately.
Inform warehouse in-charge to take initiatives for repacking of damaged container/pack if necessary.

 Sampling of packaging materials

[] Check the details given on the GRN with the manufacturers label and ensure that the “Quarantine” label affixed properly by the warehouse personnel on all packaging material containers/packs of a consignment.

[] Check the physical condition of outer pack/container/damage condition.
[] Microbiology personnel will collect sample first in sampling booth for microbial analysis (when applicable).
[] Check the physical condition such as appearance (in case of Shipper carton/Master carton, Container/Jerry can/Cap for Jerry can), winding (in case of foil/film) etc. of the packaging material for any gross abnormalities. Measure internal core diameter, total reel diameter (in case of foil/film) of three reels. [] Record all necessary information in ‘Packaging Materials Sampling Report’ (as per Annexure-IV).
[] Select number of containers/bags/packs and collect sample according to sampling plan. Repair the sampling point properly, close the container/pack and affix the ‘SAMPLED’ label in cascading manner (overlapping upto half of the status bar of the previous label) over the “QUARANTINE” label without hiding any information of the previous label. Affix ‘UNDER TEST’ label on all other containers of the consignment in the same way.

[] Enter the information about the material sampled i.e. date, GRN No., lab. control no., name of  material, code no., invoice no./challan no., manufacturer lot no., manufactured by, sampled quantity, sampled by and remarks (if any)  into the ‘Sampling Register for Packaging Material’ (as per
Annexure-III).
[] Record sampling details in ‘Packaging Materials Sampling Report’ (as per Annexure-IV).
[] If any discrepancy found, immediately inform the warehouse in-charge to take action accordingly.
[] Transfer the collected samples to QC laboratory.

Release:

[] On receipt of the packaging material sample from warehouse, QC will keep them into “Under test sample (packaging material)” labeled rack in sample receiving room or any other designated place with proper labeling.
[] Enter the sampled by (initial) in the ‘Packaging Material Log Register’ (as per Annexure-I).
[] In-charge/Sr. Executive, QC will issue the packaging material work sheet with initial and date on every page to the analyst and enter the worksheet issued by (initial and date) in the ‘Packaging Material Log Register’ (as per Annexure-I).
[] Carry out the physical appearance test very carefully.
[] Test all parameters according to the packaging material specification and the packaging material test method and record the analytical raw data and calculations, and attach the printout of weight(s) in the analyst logbook.
[] Fill up the respective Packaging material work sheet (as per Annexure-V) and attach printout of required raw data.
[] Accordingly prepare the ‘Certificate of Analysis for Packaging Material’ (as per Annexure-VI).
[] Use bracket like [  ] to indicate that the result is taken from manufacturer’s certificate of analysis (COA).
[] Keep a remarks on ‘Certificate’, if any minor observation (variation in dimension, colour etc.) is found for a batch of packaging material.
[] Compile a batch report with COA, test report (packaging material work sheet), packaging materials sampling report (prepared as per Annexure-IV), QC copy of GRN.
[] Keep one retention sample with the bunch if feasible.
[] If it is not possible to keep retention sample with the bunch, keep them into another box/pack with proper labeling.
[] Submit the batch report with respective packaging material specification to Executive/Sr. Executive, Quality Control for checking.
[] Check and verify the test result against Packaging Material Specification. Inform production department for machine trial or practical trial for a particular material, if required.
[] Executive, Production is responsible for machine trial and reporting.
[] On completion of checking/verification, enter the detail in the ERP.
[] Submit GRN, testing report and COA to In-charge/Sr. Executive, QC for checking and approval. Give part release to fulfill the production demand, if required.
[] In-charge, QC/Sr. Executive, QC will check report and approve finally for passed/rejected status of the packaging material.
[] Officer/Executive, QC will prepare status label (Passed/Rejected) after approval of GRN. The expiry and retest should be not applicable for all secondary packaging materials, glass bottle, ampoule, plastic container/cap/dropper/stopper/syringe, polyethylene bag, aluminium cap, sealing foil and alu-lid foil. In case of PVC, PVdC film and Alu-bottom foil; the expiry and/retest should be as per manufacturer’s recommendation. If not mentioned by manufacturer, then the expiry period for PVC, PVdC film and Alu-bottom foil should be five years.

[] Officer/Executive/Sr. Executive, QC will check and sign on the passed label.
[] Only the rejected label will be signed by In-charge/Sr. Executive, QC.
[] After release of consignment entry information regarding a passed/rejected GRN in “Packaging material log register” (as per Annexure-I).
[] After approval send copy of GRN to warehouse/Store.
[] QC Executive or QC sampler will affix status label (Passed/Rejected) in cascading manner (overlapping upto 3/4 th of the status bar of the previous label) over the “SAMPLED” or “UNDER TEST” label without hiding any information of the previous label.
[] Enclose mail or any other relevant document and approved GRN, with the respective batch document.
[] Keep a copy of GRN with batch document and file it up.

List of Annexes: Packaging Material Sampling and Release Procedure

[] Annexure-I     : Packaging Material Log Register
[] Annexure-II    : Sampling quantity for Packaging Material
[] Annexure-III   : Sampling Register for Packaging Material
[] Annexure-IV   : Packaging Materials Sampling Report
[] Annexure-V    : Packaging Material Work Sheet
[] Annexure-VI   : Certificate of Analysis for Packaging Material

Packaging Material Sampling and Release Procedure Read More »

Storage Conditions of Raw Materials and Packaging Materials

Storage Conditions of Raw Materials and Packaging Materials, Purpose:

The purpose of this procedure is to describe the instruction of storage conditions of raw materials and packaging materials.

Storage Conditions of Raw Materials and Packaging Materials, Scope:

This SOP is applicable for storage conditions of raw materials and packaging materials to Quarantine Area, Ambient Store, AC Store, Finished Goods Store, Capsule Shell Store and Central Warehouse of XX Pharmaceuticals Ltd.

Definitions/Abbreviation:

[] Ambient Store: Storage area with normal environment condition.
[] MSDS: Material Safety Data Sheet.

Responsibilities:

The roles and responsibility is as follows:

Executive, Warehouse

[] Maintain storage conditions of all raw and packaging materials as per Manufacturer’s instruction or according to specification.
[] Record the temperature and humidity of the material storage room.
[] Follow the instructions of this procedure correctly.

Executive, Quality Compliance

[] Verify the storage conditions of raw and packaging materials.

 General Manager, Plant

[] Ensure that all raw and packaging materials are stored properly.
[] Ensure appropriate personnel from the section are trained on this procedure and evaluate the effectiveness of training.
[] Confirm that SOP is technically sound and reflects the required working practices.

Head of Quality Assurance

[] Approval of SOP.
[] To ensure the overall implementation of the SOP.

Procedure:
Precaution(s):

[] Precautions must be taken to prevent unauthorized entry in the storage areas.
[] All stores must be secured with lock and key.

Storage Conditions:

Maintain Storage conditions as below:
[] Quarantine Area :Below 25°C
[] Ambient Store:Below 40°C
[] AC Store:Below 25°C

Finished Goods Store:Below 30°C

Capsule Shell Store:Temperature Below 25°C & Relative Humidity Below 60%
Central Warehouse:Below 25°C

 Storage of the materials:

[] Carry out the emergency plan if temperature goes above 25°C for AC store.
[] Record the temperature and humidity for the time when temperature goes above 25°C.
[] Inform QA department immediately providing all recorded data and existing product status.
[] Check the recorded data and evaluate the sensitive material, which might temperature sensitive.
[] Send the advice to Quality Control Department for retesting of that sensitive material before use in production.
[] Carry out tests as described in the respective test method.
[] Analyze the impurity of the substance, if required.
[] Affix “REJECTED” label on the existing label of the container when retesting result does not comply with specification.
[] Prepare a list for storage condition of raw materials and packaging materials as per Annexure-VII; then take approval from Head of Quality Assurance.

[] Update the list for storage condition of raw materials and packaging materials three months to yearly or when required.

Recording of storage conditions:

[] Sr. Executive/Executive, Quality Compliance will issue the ‘Temperature & Relative Humidity Record Sheet of Warehouse’ as per Annexure-I to Annexure-VI
[] Executive, Warehouse by maintaining proper record.
[] Record the temperature and humidity of Quarantine Area, Ambient Store, AC Store, Finished Goods Store, Capsule Shell Store and Central Warehouse thrice in a day in ‘Temperature & Relative Humidity Record Sheet of Warehouse’ prepared as per Annexure-I to Annexure-VI.
[] Maintain the storage condition as per QA approved Storage Condition of Raw materials and Packaging materials.

List of Annexes

1.0 Annexure-I: Temperature Record Sheet of Quarantine Area.
2.0 Annexure-II: Temperature Record Sheet of Ambient Store.
3.0 Annexure-III: Temperature Record Sheet of AC Store.
4.0 Annexure-IV: Temperature Record Sheet of Finished Goods Store.
5.0 Annexure-V: Temperature & Relative Humidity Record Sheet of Capsule Shell Store.
6.0 Annexure-VI: Temperature Record Sheet of Warehouse Central Warehouse.
7.0 Annexure-VII: Format of Storage Condition of Raw materials and Packaging materials.

 

Storage Conditions of Raw Materials and Packaging Materials Read More »

Retesting of Raw and Packaging Material Standard Operating Procedure

Purpose:

The purpose of this procedure is to describe the process for retesting of raw material and packaging materials (before retest date).

Scope:

This procedure is applicable for all raw materials (APIs and excipients) and some packaging materials received in XX Pharmaceuticals Limited.

Definitions/Abbreviation:

[][]SOP: Standard Operating Procedure.
[][]QC: Quality Control.
[][]API: Active Pharmaceuticals Ingredients

Responsibilities:

The roles and responsibility is as follows:

Officer/Executive/Sr. Executive, QC & Microbiology

[][]To ensure that the instructions of this procedure are correctly followed.
[][]To maintain the records properly as per SOP.

Executive, Warehouse

[][]To send retest request to QC in time.
[][]To ensure availability of containers to be sampled from quarantine area to the sampling booth and their replacement after sampling.
[][]To ensure cleanliness of Sampling booth and containers to be sampled.

Manager, Quality Control

[][]To ensure that this procedure is kept up to date.
[][]To confirm that the SOP reflects the required working practices.
[][]To arrange training on the SOP to all concerned personnel and to ensure implementation of the SOP after training.

Head of Quality Assurance

[][]Approval of the SOP.
[][]To ensure the overall implementation of the SOP.

Procedure:

[][]Mention the retest date on passed label at the time of first release.
[][]Frequency of re-testing will be one year from test date.
[][]If the next retest date exceeds the expiry date, assign the retest date same as expiry date.
[][]The expiry date provided by the manufacturer will not be extended in any circumstances for active raw material.
[][]In case of excipients and packaging material, the expiry date may be extended on the basis of retest result if the expiry date is mentioned as best before/use before/retest date in manufacturer’s COA.
[][]In such cases, recommended expiry will be assigned instead of expiry and the next retest frequency will be every six months.
[][]The expiry date may be extended as per manufacturer’s recommendation.
[][]If there is no manufacturer’s recommendation, the expiry date may be extended twice for every six month up to one year from expiry date on the basis of retest result.
[][]Executive, warehouse will raise ‘Retesting Advice Form’ (as per Annexure-I) by ERP for the identified raw/packaging materials subject to retest or expiry.
[][]In case of material to be retested, warehouse will send the retest advice form at least 7 days before the retest date and QC will test and release/reject retested material within the retest date.
[][]In case of material to be expired, warehouse will send the retest advice form on the expiry date and QC will reject the expired material after necessary entries in retest advice form.
[][]QC will receive retesting advice form from warehouse and enter necessary information in Raw Material Register and assign the new Lab. Control No. for retest as below:
e.g. Lab. Control No./R1
Where, Lab. Control No. is of the identified material subject to retest.
/ is separator
R1 is retest for first time (e.g. R1, R2…..)
[][]Take sample from last used container for active and excipients sufficient for necessary retest parameters to relevant test specification.

[][]Collect sample following SOP for Raw material sampling and release procedure SOP for Packaging material sampling and release procedure and affix ‘UNDER RETEST’ label on the previous ‘PASSED’ label in cascading manner.

Carryout the following tests for each raw material

[][]Description/Appearance
[][]LOD/Water Content/Moisture Content
[][]Chromatographic Purity/Related Substance
[][]Assay
[][]pH/Acidity/Alkalinity test
[][]Microbial limit test
[][]Bacterial Endotoxin test
[][]Other relevant test (If necessary)
[][]Carry out required tests as described in the respective test method.
[][]Record analytical raw data in analytical worksheet and analyst logbook. Entry all results in certificate of analysis in ERP.
[][]Verify the test report against specification in ERP.
[][]Follow SOP for handling of out of specification if the test result does not comply with the specification.
[][]After approval/rejection, take print out the COA and two copies of approved ‘Retesting Advice Form’.
[][]Attach the retest report and related documents with the previous test reports.
[][]Prepare the required number of status labels (PASSED/REJECTED) for retested material.
[][]QC will send a copy of approved ‘Retesting Advice Form’ to warehouse.

Retesting of Raw and Packaging Material Standard Operating Procedure Read More »

Manufacturing Trend Analysis Standard Operating Procedure

Manufacturing Trend Analysis, Purpose:

Manufacturing Trend Analysis, the purpose of this SOP is to define a procedure for trending of manufacturing data and to ensure that management reviews the trends and takes appropriate action.

Manufacturing Trend Analysis, Scope:

This procedure is applicable for all products manufactured at general block and are analyzed in Quality Control and Microbiology Laboratory of XX Pharmaceuticals Limited.

Definitions / Abbreviation:

[][]SOP: Standard Operating Procedure.
[][]QC: Quality Control.

Responsibilities:

[][]The roles and responsibility is as follows:
[][]Executive/Executive, QC & Microbiology
[][]To ensure that the instructions of this procedure are correctly followed.
[][]To maintain the records properly as per SOP.

Manager, Quality Control

[][]To ensure that this procedure is kept up to date.
[][]To confirm that the SOP is technically sound and reflects the required working practices.
[][]To arrange training on the SOP to all concerned personnel and to ensure implementation of the SOP after training.
[][]To ensure effective assessment of trend analysis of Product.
[][]Take correction action to prevent reoccurrence.

Head of Quality Assurance

[][]Approval of the SOP.
[][]Review all trend analysis to take appropriate action.
[][]To ensure the overall implementation of the SOP.

Procedure:

[][]Manager, Quality control will issue the ‘Finished Product Trend Card’ (Annexure-I) by making entry in the ‘Trend Card Issue Register’ (Annexure-II)
[][]QC Executive will make entry in ‘Finished Product Trend Card’ and MS Excel format at the time of report submission.

Trend the following key parameters by QC Executive taken from IPC data:

Tablet:

[][]Disintegration Test
[][]Average weight

Capsule:

[][]Disintegration Test
[][]Filled weight

Powder for suspension:

[][]Filled weight
[][]Trend the following key parameters by QC Executive taken from analytical data:

Tablet:

[][]Assay (Active content)
[][]Dissolution Test (if applicable)

Capsule:

[][]Assay(Active content)
[][]Moisture content
[][]Dissolution Test (if applicable)

Powder for suspension:

[][]Assay (Active content)
[][]Moisture content
[][]Dissolution Test (if applicable)
[][]Quality Control Manager will review the trend at the time of report approval.
[][]If there are any atypical findings that indicate potential quality or performance issues, then follow the below instruction:
[][]Carry out an immediate laboratory investigation as per procedure for out of specifications. But this action will not prevent from releasing the batch to commercial.
[][]If the laboratory investigation indicates that there is no laboratory error, then it must be reported to AGM, Quality Assurance to conduct an investigation and take action to bring the situation in control.
[][]Preserve all the data securely for Periodic Product Review.

List of Annexure:

Annexure-I: Finished Product Trend Card
Annexure-II: Trend Card Issue Register

Manufacturing Trend Analysis Standard Operating Procedure Read More »

Raw Material Sampling and Release Standard Procedure

Raw Material Sampling and Release, Purpose:

Raw Material Sampling and Release, the purpose of this procedure is to describe the process for sampling and release of the raw materials (actives and excipients).

Raw Material Sampling and Release, Scope:

This procedure is applicable for all raw materials (APIs and Excipients) received in XX Pharmaceuticals Limited.

Definitions/Abbreviation:

[][]QC: Quality Control
[][]API: Active Pharmaceuticals Ingredients
[][]GRN: Goods Received Note
[][]CoA: Certificate of Analysis
[][]AQL: Acceptance Quality Limit
[][]BOPP: Bi-axially Oriented Polypropylene
[][]Mfg. Date: Manufacturing Date
[][]Exp. Date: Expiry Date
[][]ERP: Enterprise Resource Planning
[][]SS: Stainless Steel

Responsibilities:

The roles and responsibility is as follows:

Officer/Executive, QC and Officer/Executive, Microbiology

[][]To ensure that the instructions of this procedure are correctly followed.
[][]To maintain the records properly as per SOP

Executive, Warehouse

[][]To ensure availability of containers to be sampled from quarantine area to the sampling booth and their
replacement after sampling.
[][]To ensure cleanliness of sampling booth and containers to be sampled.

Manager, Quality Control

[][]To ensure that this procedure is kept up to date.
[][]To confirm that the SOP reflects the required working practices.
[][]To arrange training on the SOP to all concerned personnel and to ensure implementation of the SOP after training.

Head of Quality Assurance

[][]Approval of the SOP.

Procedure:
General Precaution(s):

[][]Take sample for microbial testing first followed by other sampling.
[][]Use clean and dry sampling device for sampling.
[][]Use sampling device after moping with freshly prepared 70% IPA for collecting the sample for microbiological limit test.
[][]Material of only one consignment shall be sampled at a time.
[][]Use different sampling devices for sampling of different materials.
[][]For sampling of volatile and hazardous chemicals and solvents, follow instructions as given in their handling procedures.
[][]All solid as well as liquid raw materials except solvents are to be sampled in sampling booth.

Sampling: Raw Material Sampling and Release

[][]Receive the GRN for raw material from the warehouse then compare with Manufacture’s CoA and enter the details (GRN Received Date, GRN No., Lab. Control No., Name of material, Code No., Invoice/Challan No., Manufacturer Lot No., Manufactured by, Supplied by, Mfg. Date, Exp. Date, Qty. received, Received by & date) in the Raw Material Register (as per Annexure-I) maintained in QC department.
[][]If the Manufacture’s CoA is not received, inform to Supply Chain Department.
[][]Ensure that material is received from Approved Vendor.
[][]If the material is not from Approved Vendor, then the material is not to be sampled.
[][]Assign the work of sampling of the material to the QC Executive.
[][]Share the copy of GRN and Manufacturer CoA with Microbiology Laboratory, when required.
[][]Inform Warehouse to ensure cleanliness of sampling area and fill-up the Cleaning Checklist before Sampling of Raw Materials (Annexure-VIII) and then start-up of sampling booth.
[][]Assigned QC Executive will take required no. of “SAMPLED” label as per labeling SOP.
[][]Assigned QC Executive will prepare and checked ‘SAMPLING IN PROGRESS’ label (as per Annexure-II); prepare required containers/poly bags for sampling according to sampling plan for the material to be sampled.

Sampling plan

[][]In case of all active raw materials, carry out sampling from all containers in each of supplied batch for performing identification test individually for all the containers.
[][]In case of all excipient, carry out sampling from different containers in each of supplied batch according to formula √n + 1 e.g. for 10 containers sample from √10 + 1 = 4.16 ≈ 5 containers.

Sampling container

[][]Select the sample container according to the nature of the material to be sampled.
[][]Use clean fresh poly bags for solid materials.
[][]Use clean dry glass bottle with screw cap for liquid, dry amber glass bottle with screw cap for light sensitive liquid and transparent stoppered flask for solvents.
[][]Use sterilized screw capped conical flask (autoclaved at 121°C for 15 minutes) for sampling of raw material for microbial test.
[][]Sample all light sensitive solid materials in black polyethylene bag.
[][]Sample all the moisture sensitive materials in air tight container.

Sampling note: Raw Material Sampling and Release

Solid

If the material is in paper bag, take the sample by cutting a small ‘V’ on the bag and in case of Drum open the lid & inner polyethylene then push the Sampling thieve and take sample into a labeled poly-bag. Then place a clean poly-bag over the tear area and properly seal the poly-bag with adhesive tape. In case of Drum, tie the inner-polyethylene with rubber band/cable tie, finally twist the lid properly.

Liquid

Deep the liquid sampling device vertically into the sample drum and collect the sample or pipette after gently stirring the liquid and transfer the liquid sample to a labeled, cleaned container. Solvent in distorted metal drum must be sampled in addition to the rule of Ön + 1. Sample all flammable solvents in solvent dispensing room.

Sampling device

Use stainless steel sampling devices specially designed for solid and liquid material.

[][]For solid materials received in drums/container use specially designed S.S. sampling device by which material can be sampled from different level (thief sampler).
[][]For liquid and solvents received in drum, use specially designed S.S. drum sampler.
[][]For liquid material received in small container use specially designed small SS liquid sampler.
[][]For solid material received in bags use specially designed SS solid sampler/SS spoon.
[][]For microbiology analysis, use screw capped conical flask/glass bottle and SS spoon (autoclaved at 121°C for 15 minutes).
[][]Clean and maintain the sampling device (tools) as per SOP for cleaning and storage of sampling tools after completion of sampling.

Damaged containers or torn bags

[][]Check the physical condition and cleanliness of raw material containers before opening for sampling.
[][]If any container found in damaged condition, intimate warehouse in-charge.
[][]Damaged containers whose integrity is doubtful should be sampled and tested separately.
[][]Inform warehouse in-charge to take initiatives for repacking of damaged container or torn bags if necessary.

Gowning  procedure

[][]Wear fresh gown before entering into sampling booth.
[][]Wear sterile gloves, mask before sampling for microbiology analysis.
[][]Cover the hands with gloves and wear a cap and mask to cover hair and nose respectively.
[][]Cover the footwear with shoe cover.
[][]Use separate apron, nose mask, hand gloves, cap & shoe covers for sampling of different material.
[][]Mop the hands with 70% IPA and air dry before proceeding for sampling and particularly when samples are to be drawn for Microbiological testing.

Sampling procedure

[][]Check the Cleaning Checklist before Sampling of Raw Material (as per Annexure-VIII).
[][]Inform Warehouse before going for sampling to arrange the raw material containers which are to be sampled in sampling booth area and ensure the cleanliness of these containers externally, before bringing the container to be sampled to the sampling area.
[][]Enter the Warehouse (Raw Material) with sampling basket, sampling utensils, sampled label, poly-bags, GRN and ‘Sampling in progress’ label.
[][]Check the details given on the GRN with the suppliers label and ensure that the “Quarantine” label affixed by the warehouse personnel on all raw material containers of a consignment.
[][]Select number of containers/ bags as per sampling plan and inform Warehouse personnel to send the raw material containers to the material entry airlock.
[][]Check that ‘CLEANED’ label is affixed to the sampling booth and then affix the ‘Sampling in-progress’ label outside of the sampling booth. Enter the sampling booth.

Operate the sampling booth

[][]Receive the desired container(s) within material entry airlock. Check that the containers are free from dirt & dust externally. Do not sample the container/bag whose packing integrity has been lost (material has been exposed to environment).
[][]Take the raw material inside the sampling booth. Sample in a manner so that laminar airflow can be in operation without any interruption.
[][]Enter the information about the material sampled into the ‘Sampling Register’ i.e. Date, GRN No., Lab. Control No., Name of material, Code No., Manufacturer Lot no., Manufactured by,  Sampling start time (as per Annexure-IV).
[][]Wear disposable hand gloves just before start of sampling.
[][]Open the container for sampling one by one.
[][]Check the physical condition of the raw material for any gross abnormalities like dis-colourisation, lumps, foreign matter and physical heterogeneity. Record information in Raw Materials Sampling Report (as per Annexure-V).
[][]Collect the sample aseptically into sterile screw capped conical flask by sterilized sampling device for microbiology analysis.
[][]Assign the sampled Container No. as 1/25, 2/25, 13/25, 25/25 etc. with Reference to drum number of container sampled.
[][]Draw the sample from different levels of the container. (i.e. From Top, Middle & Bottom). The weight of the total sampled quantity should be according to List of Raw Material Sampling Quantity (prepared as per Annexure-III).
[][]For excipient, prepare composite sample by taking equal quantity of material from the sampled drum. Mix thoroughly in big polythene bag for retained sample and testing sample. For identification test take individual small quantity of sample from each sampled container.
[][]For active raw material, prepare composite sample during sampling for assay for every 10 containers of the consignment by taking equal quantity of material from individual sampled container. Mix thoroughly in plastic bag to make sample for assay test. For complete analysis (except identification and assay) and retention sample make composite sample by taking equal quantity from all bags or container during sampling. For identification test take individual small quantity of sample from each container.
[][]Take the individual sample from each sampled container for microbiological analysis in sterile container, if specified.

Reseal the container properly after sampling as follows: Raw Material Sampling and Release

[][]Fibre/Plastic container pack: Shrink the inside poly bag by twisting it sufficiently. Bent it & tie it using cable tie. Place the lid of container & close it tightly & seal it.
[][]Woven and Paper Bag: Close the sampling point and seal it properly using BOPP tape.
[][]Liquid RM container: Place the lid of container & keep it tightly closed.
[][]Affix yellow colour duly filled & signed ‘SAMPLED’ label on each containers from which the samples are collected and ‘UNDER TEST’ label on all containers of a consignment.
[][]After completion of sampling switch off the sampling booth.
[][]Record sampling details in Raw Materials Sampling Report (as per Annexure-V).
[][]Enter the Sampling end time, Sampled quantity, Sampled by and Remarks (if any) into the ‘Raw Material Sampling Register’ (as per Annexure-IV).
[][]Place the used sampling device in container labeled as ‘TO BE CLEANED’ containing a poly bag.
[][]Shift sampled container outside the sampling booth.
[][]Inform warehouse personnel to transfer it to quarantine area.
[][]Leave sampling booth and affix ‘TO BE CLEANED’ label outside the sampling booth. Inform warehouse personnel for cleaning.
[][]Warehouse personnel will clean the sampling booth, enter the sampling booth cleaned by in ‘Raw Material Sampling Register’ (as per Annexure-IV) and then affix ‘CLEANED’ label outside the sampling booth.
[][]If any discrepancy found, immediately inform the warehouse in-charge.
[][]Keep the collected samples in the sample receiving room of QC Laboratory in dedicated rack for Raw Material or in refrigerator, if specified.
[][]Keep the retention sample in retention sample room or in refrigerator, if specified.
[][]Enter the sampled by (initial) and date in the ‘Raw Material Log Register’ (as per Annexure-I).

Release:

[][]Enter the sampled by (initial) and date in the ‘Raw Material Log Register’ (as per Annexure-I).
Issue the Raw Material Analytical Work Sheet (as per Annexure-VI) (for commercial raw material) with initial and date on every sheet to the analyst and enter the worksheet issued by (initial and date) in the ‘Raw Material Log Register’ (as per Annexure-I).
[][]Carry out the physical appearance and identification test separately for active raw material from each container.
[][]Microbiology will perform microbial limit test from all sampled container and bacterial endotoxins test from composite sample.
[][]Perform identification test of excipient from all sampled containers.
[][]For active raw materials, prepare sub-composite sample from each 10 container and then prepare composite sample from all the sub-composite samples. Perform the test of sub-composite sample if composite sample shows out of specification result to identify easily which container(s) is in problem. Retain all the sub-composite samples until release of the material.
[][]For active raw materials perform rest of the test as per the specification from the composite sample prepared from all containers. Carry out assay test from the composite sample and take result.
[][]For excipient perform the complete test as per specification from the composite sample prepared from the sampled containers.
[][]Check the appearance of capsule shell according to Sampling Plan for Normal Inspection of Capsule Shell (as per Annexure-IX).
[][]Test all parameters according to the Raw Material Specification and analyze the batch exactly as written in the method of analysis.
[][]Record all analytical raw data and calculations, and attach the printout of weight(s) in the analyst logbook.
[][]Fill up the Raw Material Analytical Work Sheet (as per Annexure-VI) and attach printout of required raw data.
[][]Weigh the sample ± 5.0% of specified quantity for assay test and ±10.0% of specified quantity for all other tests.
[][]Use bracket like [ ] to indicate that the result is taken from manufacturer’s/supplier’s certificate of analysis (CoA) (if available).
[][]Entry all data in previously created certificate of analysis for raw materials in ERP (as per Annexure-VII).
[][]Verify the test report with specification followed by Approval/Rejection in ERP.
[][]Follow SOP for handling of out of specification if the test result does not comply with the specification.
[][]After approval/rejection print out the COA and two copies of GRN under the heading of

  • Approved/Rejected quantity.
  • Date of Release/Rejected.
  • Approved/Rejected status.

[][]Submit all report to QC Manager for approval.
[][]Submit one copy of GRN with the initial with date of In-Charge, QC or his/her designee to store.
[][]Compile a bunch with CoA (as per Annexure-VII), filled Raw Material Analytical Work Sheet (as per Annexure-VI) and raw data, Raw Materials Sampling Report (as per Annexure-V), QC copy of GRN after approval.
[][]Fill up the Trend Card with necessary data.
[][]Prepare the required number of green “PASSED” label for passed.
[][]In case of Rejection, prepare the required no. of red “REJECTED” label.
[][]Fill up the Raw Material Rejection Form (as per Annexure-X) for rejection of raw material.
[][]Paste “PASSED”/“REJECTED” label in cascading manner (overlapping upto 3/4 th of the status bar of the previous label) over the “UNDER TEST” label without hiding any information of the previous label.

List of Annexes: Raw Material Sampling and Release

Raw Material Sampling and Release Standard Procedure Read More »

Sampling Tools Cleaning and Storage SOP

Sampling Tools Cleaning and Storage; Purpose:

Sampling Tools Cleaning and Storage; The purpose of this procedure is to describe the instruction of cleaning and storage of sampling tools.

Sampling Tools Scope:

This SOP is applicable to sampling tools used for Quality Control Laboratory and Microbiology Laboratory at XX Pharmaceuticals Ltd.

Definitions/Abbreviation:

[][]SOP: Standard Operating Procedure: A written authorized procedure, which gives instructions for performing operations.
[][]QC: Quality Control.

Responsibilities:

[][]The roles and responsibility is as follows:
[][]Laboratory Attendant, QC & Microbiology
[][]To prepare of cleaning solution.
[][]To clean and store all sampling tools by following SOP.
[][]Executive, QC & Microbiology
[][]To ensure that this procedure is followed.
[][]To maintain the records properly as per SOP.

Manager, Quality Control

[][]To ensure that this procedure is kept up to date.
[][]To confirm that the SOP is technically sound and reflects the required working practices.
[][]Arrange training on the SOP to all concerned personnel.
[][]To ensure implementation of the SOP after training.
[][]Schedule calibration of the instrument at the defined intervals.

Head of Quality Assurance

[][]Approval of the SOP.
[][]To ensure overall implementation of this SOP.

Procedure:

Precaution(s):
[][]Wear hand gloves, mask and protective clothing before cleaning of sampling tools.
[][]Be sure that the sampling tools are cleaned just after use.
[][]After cleaning of tools, be sure that the tools are free from any residual content of detergent or sample.
[][]During handling, sterilized gloves should be worn after sterilization of microbiology sampling tools.
Cleaning of Sampling Tools:

For scoop/spoon:

[][]Clean the sampling devices with potable water following by 0.5% soap or detergent solution.
[][]Finally rinse with purified water to remove the adhering material.
[][]Check the cleanliness physically and clean again if necessary.
[][]Dry in hot air oven for use in QC sampling.
[][]Sterilize at 2000C for 1 hour or autoclave at 1210C for 15 minutes for the sampling of Microbiology analysis.

For pipette (glass) and Glass Rods:

[][]Pass the running potable water through the pipette to remove the adhering material.
[][]Sink the pipette into 0.5% soap or detergent solution.
[][]Rinse with potable water to remove detergent.
[][]Finally rinse with purified water.
[][]Confirm that the tools are cleaned properly, clean again if it is necessary.
[][]Dry in hot air oven for use in QC sampling.
[][]Sterilize at 2000C for 1 hour or autoclave at 1210C for 15 minutes for the sampling of Microbiology.

Storage of Sampling Tools:

[][]After dry, remove the cleaned tools from the oven and wrap the dry tools individually with cleaned polybag.
[][]Ensure that there is no exposure of sampling tools after wrapping the cleaned dried tools with polybag.
[][]Finally keep it at closed condition.
[][]Affix the tag “CLEANED” label duly signed with date on the sampling tools.
[][]Use the tools within 7 days sampling of Chemical test and within 24 hours for sampling of microbiology test.

Sampling Tools Cleaning and Storage SOP Read More »

Sampling Booth Start-up, Operation and Cleaning

Sampling booth Purpose:

The purpose of this SOP is to describe the operation and cleaning procedure of Sampling Booth in order to comply with cGMP standard.

Sampling booth Scope :
The scope of the procedure is applicable to the Sampling Booth installed at the Warehouse of general block of XX Pharmaceuticals Limited.

Definitions/Abbreviation:

[][]SOP: Standard Operating Procedure
[][]QC: Quality Control

Responsibilities:

The Roles and Responsibilities are as follows:

Officer/Executive/Sr. Executive, Quality Control

[][]To ensure that this procedure is followed.
[][]To maintain the records properly as per SOP.

Executive, Warehouse

[][]To ensure that this procedure is followed.
[][]To check & ensure cleaning of sampling booth.

Manager, Quality Control

[][]To confirm that the SOP is technically sound and reflect the required working practice.
[][]To arrange the training on the SOP to all concerned personnel and to ensure the implementation of the SOP after training.

Head of Quality Assurance

[][]To approve the Document
[][]To ensure the overall implementation of the SOP.

Procedure

Precautions:
[][]The working person must follow safety procedures of works.
[][]For any trouble, disturbance switch OFF the Sampling Booth.
[][]Don’t sampling solvent and flammable liquid inside the sampling booth

Operation

[][]Check the Sampling Booth first physically.
[][]Check electric connection and mechanical set up.
[][]Machine switch on.
[][]Light on and blower on.
[][]Open the door.
[][]After completion desired work clean the Laminar Unit properly.
[][]Close the door and switch off main switch.
[][]Switch ON Sampling Booth.
[][]Switch ON Light.
[][]Switch ON the Laminar Air Flow.
[][]Increase or decrease air flow by pressing up/down button.
[][]Operate the Sampling Booth for 30 minutes before starting sampling.
[][]Record the machine operation start time & end time and other parameters on the  Equipment Log Book’

Cleaning

[][]Remove dust from the Sampling Booth with a vacuum cleaner and then clean with lint free cloth.
[][]Clean the booth with wet mop.
[][]Wipe the water with lint free cloth.
[][]After final cleaning affix the ‘CLEANED’ label.
[][]Record the cleaning status in the ‘Equipment Log Book’.

Download Here:

[][]Annexure I: Equipment Log Book

Sampling Booth Start-up, Operation and Cleaning Read More »

Instrument calibration Standard operating procedure

Instrument calibration Purpose:

Instrument calibration, This SOP ensures that all type laboratory instruments of QC, PD, IPQC, Microbiology and balances of Production department are appropriately calibrated and calibration status maintained on due time.

Scope :

This procedure is applicable for calibration frequency of all types of laboratory instruments installed in QC, PD, IPQC, Microbiology and balances of Production department of General Block of XX Pharmaceuticals Ltd.

Definitions :

[][]QC: Quality Control.
[][]ENG: Engineering department.
[][]PD: Product development.
[][]IPQC: In-process Quality Control.

Responsibilities:

The roles and responsibility is as follows:

Officer/ Executive

[][]Ensure that the instructions of this procedure are correctly followed.
[][]Ensure that all equipment’s are included in the Instrument list.
[][]Maintain and track the calibration schedule.
[][]Ensure that all equipment’s bear appropriate calibration label and are used after calibration.
[][]To verify the third party calibration report and raw data.

Manager, Quality Control

[][]Ensure that this procedure is kept up to date.
[][]Ensure that the calibration requirement are assessed and are fully documented for all pieces of the instrument.
[][]Ensure appropriate personnel from the section are trained on this procedure.
[][]Confirm that SOP is technically sound and reflects the required working practices.

Manager, Quality Assurance

[][]Approval of SOP.
[][]Approval of calibration frequency and calibration schedule.

Precaution(s):

[][]There are no significant hazards or special instructions relating to the process/activities described in this SOP.

Procedure:

[][]Calibrate the equipment regularly as per frequency stated in the instrument calibration frequency (prepared as per format in Annexure-I) and as per calibration due date stated in the instrument calibration schedule (prepared as per format in Annexure-II) for individual equipment.
[][]Review the instrument calibration frequency when new instrument is included.
[][]Review the instrument calibration schedule yearly.
[][]Mention the responsibility (Third Party / Supplier name) for external calibration and (calibrator name and department) for internal calibration.
[][]Calibrate the instrument within 3 days of calibration due for monthly calibration period, within 7 days of calibration due for 3 and 6 monthly calibration period and 15 days of calibration due for yearly calibration period.
[][]In case of any breakdown or replacement of any damaged part where calibration needs to be carried out, the calibration schedule will be reviewed accordingly.
[][]Executive/ Sr. Executive of respective department will intimate the Engineering department/ Supplier service engineer/ outside agencies for the calibration of the instruments/ equipments.
[][]Maintain all standards, reagents, instruments and equipments etc. required for calibration.
[][]Calibrate the instrument across the operating range at a frequency appropriate to the reliability and frequency of use. Tolerance must be specified and should reflect the manufacturer’s specification or process tolerance or whichever the tightest.
[][]Re-evaluate calibration requirement immediately if there is any change in the instrument in use.
[][]Calibration must be performed by trained personnel or by approved Third Party Service Engineer.
[][]Calibration record must include:
=>Equipment name, model number and instrument ID No.
=>The name of the person who carried out the calibration.
=>Date of calibration.
=>The date when calibration is next due.
[][]For calibration, use reference standards or reference instruments whose calibration is traceable.
[][]Store the calibration device, certified standard weight in a secure place.
[][]For internal calibration, affix the calibration sticker label “ CALIBRATED” (format of calibration labels should be as per SOP: Calibration management program, Ref. No. SOP/ENG/00Y/XX, where XX refers to current version no.), with performer initial, date of completion and calibration due.
[][]For external calibration, affix the calibration sticker provided by external calibrator with performer’s initial, date of completion and calibration due.
[][]If the instrument is found out of tolerance/ limit during calibration, a label ‘Out of calibration” will be affixed on the instrument (as per SOP: Calibration management program No. SOP/ENG/00Y/XX, where XX refers to current version no.).

Notify the relevant person/ department/ organization to repair (or replace if necessary) the instrument in a timely manner.

 

Download

Annexure I Instrument Calibration Frequency
Annexure II Instrument Calibration Schedule

Instrument calibration Standard operating procedure Read More »

Assigning of laboratory control number for different items

Assigning of laboratory control number; Purpose

The tenacity of this SOP is to define the procedure of assigning Laboratory control number (Lab. Control No.) of all type raw material, packaging material, water, intermediate, bulk and finished product that are analyzed in Quality Control and Microbiology Laboratory.

Assigning of laboratory control number; Scope

This procedure is applicable for all type of raw materials, packaging materials, water, intermediate, bulk and finished products of XX Pharmaceuticals Limited.

Definitions / Abbreviation:

[] GRN: Goods Received Note

[] Lab. Control No.: A system of alpha-numerical number which represents request for analysis of materials/ water/ products received from respective department.

[] QC: Quality Control.

[] SAF: Sampling Advice Form

Responsibilities

The roles and responsibility is as follows:

[] Sr. Executive/Executive, Quality Control & Microbiology

[] To confirm that this procedure is followed.

[] To maintain the records properly as per SOP.

Assistant Manager, Quality Control

[] To confirm that this procedure is kept up to date.

[] To check that the SOP reflects the required working practices.

[] Organize training on the SOP to all concerned personnel.

[] To confirm implementation of the SOP after training.

Head of Quality Assurance

[] To ensure the overall implementation of the SOP.

[] Take initiative to Approval of the SOP.

Procedure:

[] All newly delivered samples & the accompanying documents (e.g. test request) must be assigned a separate registration number.

[] Assign Laboratory control number (Lab. Control No.) in following way:

Put first two or three letters according to the abbreviations mentioned below –

  • BBW     Boiler Blowdown Water
  • BFW     Boiler Feed Water
  • CTW     Cooling Tower Water
  • DW       Drinking Water
  • EM       Environment Monitoring
  • ET        Endotoxin Test
  • ETP      Effluent Treatment Water
  • FP        Bulk Product (Semi-Finished)
  • GMB     General Microbiology
  • PM       Packaging Material
  • PMS     Packaging Material of Source Approval
  • PSC     Purified Steam Condensate
  • PTW     Potable Water
  • PW       Purified Water
  • RM       Raw Material
  • RMS     Raw Material of Source Approval
  • SHC     Sodium Hypochlorite
  • ST        Sterility Test
  • STB      Stability Sample
  • WFI      Water for Injection
  • WW      Wash Water

Write down a hyphen (-) after the abbreviation, then serial number consist of three digits i.e. 001, then a  slash and put two digits of month i.e. 08 for month August.

Again write down a slash (/) then last two digits of the year i.e. XX for year 20XX. For example, first raw material received on August 20XX will get the Lab. Control No.: RM-001/08/XX.

GMB will be included before abbreviation of each test in case of microbiology lab control no./lab reference no. and put slash (/) after that.

Record Lab. Control No. in Register against each GRN / SAF.

Record the same in respective documents and status label also.

Assigning of laboratory control number for different items Read More »